Advantech ADAM-6060

SPHINX en Europe «  ch es uk de at dk it nl be  «
Tél: +33 (0)2 5109 2660 |  Mentions légales |  Contact |  FAQ |  Blog | 

Vous êtes ici « Advantech ADAM-6060 »

Advantech ADAM-6060


6-ch Digital Input and 6-ch Relay Modbus TCP Module

Fonctionnalités et Avantages


ADAM-6000 modules are empowered by peer-to-peer (P2P) and Graphic Condition Logic (GCL), and can perform as standalone products for measurement, control and automation. Instead of having additional controllers or programming, system configurations can be done in an extremely short time with the easy-to-use and intuitive graphic utility.

Group Configuration Capability for Multiple Module Setup
To aid configuration and save time, engineers can configure and upgrade the firmware of multiple ADAM-6000s simultaneously

Remote Monitoring and Control with Smart Phone
With support for HTML5, the ADAM-6000 can be monitored and controlled from any browser on mobile devices whilst in the field and when the engineer is connected to their network.

Advanced Security and High Reliability
ADAM-6000 Ethernet I/O modules have fast response time, and advanced security and reliability. When communication is broken, the digital output module can generate pre- defined values to ensure safety.

Modules will actively update the input channel status to specific output channels. Without dealing with the trouble of long distance wiring, users can define the mapping between a pair of modules.

Graphic Condition Logic
Users can define the control logic rules through graphical configuration Utility, and download defined logic rules to specific ADAM module. Then, it will execute the logic rules automatically just like a standalone controller.


Plus d'information

Digital Input


Dry Contact
Logic level 0: close to GND
Logic level 1: open

Wet Contact
Logic level 0: 3 V DC
Logic level 1: 10 ~ 30 V DC

Supports 3 kHz Counter Input (32-bit + 1-bit overflow)

Keep/Discard Counter Value when Power-off

Supports 3 kHz Frequency Input

Supports Inverted DI Status

Relay Output (Form A)


Contact Rating
120 V AC @ 0.5 A, 30 V DC @ 1 A (Resistive)

Breakdown Voltage
500 V AC (50/60 Hz)

Relay On Time
7 ms

Relay Off Time
3 ms

Total Switching Time
10 ms

Insulation Resistance
1 G Ω min. at 500 VDC

Maximum Switching Rate (at rated load)
20 operations/minute

Supports Pulse Output



Power Consumption
3 W (max) @ 24 V DC

RJ-45 (Ethernet),Plug-in screw terminal block (I/O and power)

System (1.6 second) and Communication (programmable)

Power Input
10 ~ 30 V DC

Dimensions (W x H x D)
70 x 122 x 27 mm


DIN 35 rail, stack, wall

Supports Peer-to-Peer, GCL

Supports User Defined Modbus Address

Supports Modbus/TCP, TCP/IP, UDP, DHCP and HTTP Protocols


Power Reversal Protection

Isolation Protection
2,000 V DC


Operating Temperature
-20 ~ 70C (-4 ~ 158F)

Storage Temperature
-30 ~ 80C (-22 ~ 176F)

Operating Humidity
20 ~ 95% RH (non-condensing)

Storage Humidity
0 ~ 95% RH (non-condensing)


.NET Class Library (SDK)
Adam/Apax .NET Utility

Ordering Information

ADAM-6060 6-ch DI and 6-ch Relay Modbus TCP Module


PWR-242 DIN-rail Power Supply (2.1A Output Current)
PWR-243 Panel Mount Power Supply (3A Output Current)
PWR-244 Panel Mount Power Supply (4.2A Output Current)


PCLS-ADAMVIEW32 ADAMView Data Acquisition Software
PCLS-OPC/MTP30 OPC Server for Modbus/TCP protocol


Fiche technique Advantech ADAM-6060 Datasheet (276.5 kB)